Power protection / Online UPS

Krykard · made by Atandra Energy
SX
Online UPS, 3-phase in, 3-phase out
10 to 120 kVA
A three-phase online UPS with an isolation transformer built in.
- Eight models from 10 to 120 kVA
- Isolation transformer built in
- Units can run in parallel
01 Models
| Model | Rated Capacity | Net Weight (kg) |
|---|---|---|
| SX-10 | 10 kVA / 9 kW | 158 |
| SX-20 | 20 kVA / 18 kW | 175 |
| SX-30 | 30 kVA / 27 kW | 210 |
| SX-40 | 40 kVA / 36 kW | 260 |
| SX-60 | 60 kVA / 54 kW | 460 |
| SX-80 | 80 kVA / 72 kW | 590 |
| SX-100 | 100 kVA / 90 kW | 630 |
| SX-120 | 120 kVA / 108 kW | 690 |
02 Specification
| Input | |
|---|---|
| Input Wiring | Three-phase five-wire (3Φ + N + PE) |
| Rated Voltage | 380 / 400 / 415 Vac |
| Voltage Range | 285 V - 475 V |
| Rated Frequency | 50 / 60 Hz |
| Frequency Range | 50 / 60 Hz +5 Hz |
| Bypass Voltage Range | +20% (settable) |
| Delayed start of Rectifier | 1~ 300s (settable via display panel) |
| Output | |
| Output Wiring | Three-phase five-wire (3Φ + N + PE) |
| Rated Voltage | 380 / 400 / 415 Vac |
| Voltage Regulation | ±1% |
| Frequency | Synchronized with utility in mains mode; 50 / 60 Hz ±0.1% in battery mode |
| Waveform | Sinusoidal |
| Power Factor | 0.9 |
| Crest Factor | 3:1 |
| Total Harmonic Distortion (THDv) | = < 1% (linear load); = < 5% (non-linear load) |
| Transfer Time | 0ms in AC mode to Battery mode; 0 ms in Inverter mode to Bypass mode |
| Inverter Overload Capability | 105% Continuous, 105% ~ 110% for 60 min, 111% ~ 125% for 10 min |
| Batteries | |
| DC Voltage | 12 V x configured battery number (settable via display panel), VRLA, Lithium-ion batteries |
| No. of Batteries | 32 pcs (28 ~ 32 selectable) |
| Charging Current | Settable as per battery capacity |
| Charging | Three - stage charging, auto switch floating / equalizing charge |
| Battery Self-Test | Settable periodic self-test; manually configurable test time and voltage |
| System | |
| Efficiency | Up to 93% in Online mode, ≥ 98% in ECO mode |
| Max. no. of Parallel Connections | 6 |
| Protections | Short-circuit, Over load, Over temperature, Low battery, Over voltage, Under voltage & Fan Failure |
| Communications | Standard configuration: RS 232, RS 485, Dry contacts Optional configuration: SNMP |
| IP rating | IP 20 |
| Display | 7 inches LCD touch screen |
| Others | |
| Operating Temperature | 0° C ~ 40° C |
| Storage Temperature | -25° C ~ 55° C (without battery) |
| Relative Humidity | 0% ~95% (non-condensing) |
Figures are from Atandra Energy's Krykard Online UPS brochure (December 2025). Rows that vary by model in ways the brochure does not state clearly are left out. Please confirm against the current data sheet before ordering; we will send it with the quotation.