Power protection / Voltage stabilisers

Krykard · made by Atandra Energy
Servo stabiliser, 3-phase
Servo voltage stabiliser, 3-phase
From 3 kVA
Holds a three-phase supply steady for machines and whole plants. Air-cooled or oil-cooled.
- Air-cooled from 3 to 150 kVA
- Oil-cooled for larger ratings
- Output held within 1%; efficiency above 98%
01 Specification
| Parameter | Air Cooled | Oil Cooled |
|---|---|---|
| Rating (kVA) | 3 kVA - 150 kVA | 3 kVA - 4000 kVA |
| Type of Cooling | Air | Oil |
| Input Voltage Range (V L-L)* | 310 V - 480 V / 340 V - 480 V / 360 V - 460 V / 360 V - 480 V | |
| Output Voltage Range (V L-L)* | 415 V (380 V / 400 V - optional) | |
| Output Voltage Regulation | 1% of nominal output voltage | |
| Input Frequency Range | 47 Hz - 53 Hz | |
| Efficiency | > 98% | |
| Effect of Load Power Factor | Nil | |
| Waveform Distortion | Nil | |
| Type of Servo Control | Micro Controller based True RMS sensing and correction | |
| Servo Motor Drive | Triac based drive for AC step synchronous motor | |
| Under / Over Voltage Cutoff * | Electronic cutoff circuit with graded time delay, set @ +5% / -10% of nominal output voltage | |
| Overload Cutoff | CT based electronic cutoff circuit with graded time delay set @ 110% of rated full load current | |
| Short Circuit Protection | MCB / MCCB provided up to 100 kVA; HRC fuse provided for 125 - 175 kVA; Optional >200 kVA | |
| Single Phasing Prevention | Provided in AU / OU models only; Not provided in the AR / OR models | |
| Phase Reversal Trip | Provided in AU / OU models only; Not provided in the AR / OR models | |
| Stabiliser Bypass | Provided up to 50 kVA 3 - phase; Optional > 50 kVA | |
| Transient Supression | Spike suppression through MOV is provided (Surge Arrestor is optional) | |
| Emergency Off Switch | Provided in AU / OU models only; Not provided in the AR / OR models | |
| Frequency Cutoff Protection | Optional | |
| Input High Voltage Trip | Optional | |
| Resetting Mode | Manual / Auto option provided with programmable time delay | |
| Display Type | 2 line LCD panel | |
| Parameters Displayed | Input & Output Voltages (Line & Phase), Output Currents & Frequency | |
| Input / Output Terminations | Bolted terminals up to 100 kVA, Busbar 125 kVA & above | |
| Standards | IS 9815 ( Part -1); 1994 | |
Figures are from Atandra Energy's Krykard Power Conditioners brochure (March 2025). Rows that vary by model in ways the brochure does not state clearly are left out. Please confirm against the current data sheet before ordering; we will send it with the quotation.
02 Other Krykard ranges